Docs / Inverters
Lumentree
GridEon reads Lumentree inverters through the RS485 communication port, using the Modbus RTU protocol.
Step 1 · Find the inverter's RS485 port
Look in the inverter manual for the RS485 (Modbus) communication port and the pins for lines A (+) and B (−).
Good to knowThe battery BMS port and the RS485 monitoring port are usually different ports. Use the monitoring one.
Step 2 · Connect the USB–RS485 adapter
- A on the inverter to A (+) on the adapter
- B on the inverter to B (−) on the adapter
- GND, if both the adapter and the port have it
Use a twisted pair for A and B. Plug the adapter into a USB port on the GridEon device.
Step 3 · Set up the inverter in GridEon
Go to Settings → Inverter, choose Lumentree as the brand, then the model and the adapter's serial port. Save.
Step 4 · Check the data
On the Devices page, the inverter should show Online, with its serial number, power and output voltage.
Troubleshooting
- The inverter stays Offline: swap the A and B wires. This is the most common cause.
- Data drops out now and then: shorten the cable or use shielded twisted-pair cable.
- The serial port doesn't appear: unplug and replug the adapter, then reload the settings page.